Catalog, under Systems: Standards (/standards, with standard:read, covered by every viewer’s *:read floor) is the directory of standards: the contracts your systems are built to. A Huddle Room, a Classroom, an Auditorium are standards; the meeting room on the third floor is a system that conforms to one. Each row shows the name (the operator-facing name, for example huddle-room), the label, its parent standard if it is a variant, and its origin. A standard also carries an id, a uuid minted by the database, the internal address the handle resolves to (ADR-0062); the handle is what you type and read.

A standard is the system-side counterpart of a product. A product says what a component is and what it carries; a standard says what a system is built to be and what it carries. It was formerly a bare label catalog that carried no contract, and its promotion into a first-class catalog entity is why it has its own page and its own standard:* permission rather than sitting under the shared type catalog (ADR-0048).

A standard is not a system type. They are two axes and a system can carry either, both, or neither. The system type (Catalog, under Systems: Types) says what a system is for, meeting, teaching, signage; the standard is the contract it is built to. One fleet holds ten signage standards and six classroom standards under a single type, which is why the classifier is its own catalog rather than a use of a standard’s own parent-variant chain (ADR-0096).

  • Conforming is optional. A system points at a standard through its Standard field, and leaving it empty is legitimate: a one-off system that matches no standard carries only its own values, exactly as a component with no product does.
  • Variants use parent standard. A specific standard that refines a broader one points at it with parent standard (a Large Classroom under Classroom). A standard with no parent is a base standard.
  • New standard (with standard:create, an admin permission) opens a create drawer: give it a name (unique tenant-wide, e.g. lecture-hall) and a label, and optionally pick a parent standard. An unknown parent is refused (422).
  • Pick a row to open its detail blade. The footer Edit pencil (with standard:update) edits the label and parent. The blade does not edit the name: rename a standard you created with omniglass standard rename <name> --name <new> (standard:rename), which keeps every system that conforms to it. Delete (with standard:delete) removes the row, behind a confirm.
  • Delete is refused (409) while a system still conforms to it. Repoint or remove those systems first.

The same operations are omniglass standard list/get/create/update/delete from the CLI (see the CLI reference).

A fresh install holds no standards. Omniglass ships a catalog of standard templates instead, examples you create a standard of your own from (templates). The ones this release ships, rendered from the catalog:

TemplateVariant ofSlots a fork declares
auditorium (Auditorium) projection (quorum 1, accepts projector) confidence-display (quorum 1, accepts display) stage-mic (quorum 2, accepts wireless-mic) podium-mic (quorum 1, accepts gooseneck-mic) dsp (quorum 1, accepts dsp) amplifier (quorum 2, accepts amplifier) speakers (quorum 4, accepts speaker) video-switcher (quorum 1, accepts presentation-switcher) control-system (quorum 1, accepts control-processor) touch-control (quorum 1, accepts touch-panel) camera (quorum 2, accepts camera)
classroom (Classroom) class-display (quorum 1, accepts display) instructor-mic (quorum 1, accepts wireless-mic) touch-control (quorum 1, accepts touch-panel)
digital-sign (Digital Sign) panel (quorum 1, accepts display) player (quorum 1, accepts media-player)
divisible-conference (Divisible Conference) video-bar (quorum 1, accepts video-bar) camera (quorum 1, accepts camera) codec (quorum 1, accepts codec) main-display (quorum 2, accepts display) room-mic (quorum 2, accepts ceiling-mic) wireless-mic (quorum 1, accepts wireless-mic) dsp (quorum 1, accepts dsp) amplifier (quorum 1, accepts amplifier) control-system (quorum 1, accepts control-processor) video-switcher (quorum 1, accepts presentation-switcher) display-endpoint (quorum 1, accepts av-extender) power (quorum 1, accepts power-device) touch-control (quorum 1, accepts touch-panel) scheduling-panel (quorum 1, accepts scheduling-panel) people-counter (quorum 1, accepts occupancy-sensor) projection (quorum 1, accepts projector)
ds55 (Digital Sign 55) digital-sign panel (quorum 1, accepts display, pins boreal-edge-55) player (quorum 1, accepts media-player)
ds75 (Digital Sign 75) digital-sign panel (quorum 1, accepts display, pins boreal-edge-75) player (quorum 1, accepts media-player)
huddle-room (Huddle Room) main-display (quorum 1, accepts display) conf-bar (quorum 1, accepts video-bar) conf-codec (quorum 1, accepts codec) conf-camera (quorum 1, accepts camera) conf-dsp (quorum 1, accepts dsp) conf-amp (quorum 1, accepts amplifier) conf-mic (quorum 1, accepts mic)
meeting-room (Meeting Room) video-bar (quorum 1, accepts video-bar) main-display (quorum 1, accepts display) touch-control (quorum 1, accepts touch-panel) scheduling-panel (quorum 1, accepts scheduling-panel)
mr55 (Meeting Room 55) meeting-room video-bar (quorum 1, accepts video-bar) main-display (quorum 1, accepts display, pins boreal-edge-55) touch-control (quorum 1, accepts touch-panel) scheduling-panel (quorum 1, accepts scheduling-panel)
mr65 (Meeting Room 65) meeting-room video-bar (quorum 1, accepts video-bar) main-display (quorum 1, accepts display, pins boreal-edge-65) touch-control (quorum 1, accepts touch-panel) scheduling-panel (quorum 1, accepts scheduling-panel)
mr75 (Meeting Room 75) meeting-room video-bar (quorum 1, accepts video-bar) main-display (quorum 1, accepts display, pins boreal-edge-75) touch-control (quorum 1, accepts touch-panel) scheduling-panel (quorum 1, accepts scheduling-panel)
mr86 (Meeting Room 86) meeting-room video-bar (quorum 1, accepts video-bar) main-display (quorum 1, accepts display, pins boreal-edge-86) touch-control (quorum 1, accepts touch-panel) scheduling-panel (quorum 1, accepts scheduling-panel)
mr98 (Meeting Room 98) meeting-room video-bar (quorum 1, accepts video-bar) main-display (quorum 1, accepts display, pins boreal-edge-98) touch-control (quorum 1, accepts touch-panel) scheduling-panel (quorum 1, accepts scheduling-panel)
training-room (Training Room) front-display (quorum 2, accepts display, pins boreal-edge-86) ceiling-mic (quorum 2, accepts ceiling-mic) presenter-mic (quorum 1, accepts wireless-mic) podium-mic (quorum 1, accepts gooseneck-mic) dsp (quorum 1, accepts dsp) amplifier (quorum 1, accepts amplifier) speakers (quorum 4, accepts speaker) video-switcher (quorum 1, accepts presentation-switcher) display-endpoint (quorum 2, accepts av-extender) control-system (quorum 1, accepts control-processor) touch-control (quorum 1, accepts touch-panel) scheduling-panel (quorum 1, accepts scheduling-panel) people-counter (quorum 1, accepts occupancy-sensor) camera (quorum 2, accepts camera)

In the console, the New standard drawer offers From scratch (the form above) or From a template: pick one of the standard templates, read the slots and choices it would write, give the standard a name if you want one of your own, and Create standard lands on your new standard’s panel with a note that it is yours now (starting from a template). Creating one from a template (with standard:create, POST /standards:createFromTemplate) writes one standard, not official and not read-only, carrying the template’s slots, choices, property and metric contract lines and map, in one write:

Terminal window
omniglass standard createFromTemplate --template meeting-room
omniglass standard createFromTemplate --template meeting-room --name hq-meeting --label "HQ Meeting"
  • The name is the template’s unless you give one, and a taken name is refused (409), so the same template makes two standards only under two names. Each is independent of the other.
  • A variant needs its parent first. mr55 hangs off meeting-room: create a standard from meeting-room first (or name the standard it should hang off with --parent), or the create is refused (422) naming the template to create from first. Chains are not created in one call.
  • Nothing points back at the template. The standard is audited once as a create, its from_template naming the template it came from, and that audit row is the only trace. A later release can rework the template in any way without touching your standard, and your standard renames, edits and deletes like any you created. Nothing plants it again on the next boot.

This is the clone model of ADR-0071: the thing the vendor updates (the template) and the thing you own (the standard) are two different objects, which is the whole point. A fleet that booted an older release holds the standards that release planted; they are ordinary rows of yours now, renameable and deletable, and they do not return.

The exception is the canonical vocabulary: the property, metric, event and command catalogs are the shared namespace a driver maps onto, so they must read the same on every install. Those entries stay official and read-only, and a release can correct them. See the seed model for the full reasoning.

Declared properties: the standard’s contract

Section titled “Declared properties: the standard’s contract”

A standard’s blade carries a Declared properties panel, its contract: which properties every system conforming to it exposes, and what each one defaults to. It is the same editor as a product’s contract, on the system side.

  • Declare a property (with standard:update) picks a name from the property catalog, optionally types a default, and optionally marks it required. The property must already exist in the catalog, since the contract only names it: mint it under Catalog, under Telemetry: Properties first. Declaring is idempotent, so declaring a property already on the contract revises that line in place.
  • The default is typed by the catalog, not here. Type and validation live on the property, so a standard cannot redefine what room-capacity means, only what a system conforming to it starts with.
  • Conformance is live, not a copy. A system does not copy its standard. Change a contract default and every conforming system that has not overridden that property picks up the new value immediately. Only a system’s own override survives the change.
  • Required means a conforming system must resolve the property to a value; the system’s Properties panel blocks Save while a required property is empty.
  • Withdraw (with standard:delete, from the blade’s edit mode, so the pencil’s standard:update is also in the path; behind a confirm) removes a line. Conforming systems keep any value they set for it; it simply reads as off contract from then on.

From the CLI the contract is omniglass standard property list meeting-room, omniglass standard property update meeting-room <property>, and omniglass standard property delete meeting-room <property>.

Slots: what a conforming system needs filled

Section titled “Slots: what a conforming system needs filled”

A contract says what a system carries. A slot says what it needs filled: a room microphone, a main display, a confidence monitor. Declare a slot on a standard and every conforming system inherits it, the same live inheritance the contract has, so a standard is not only a shape but a checklist that says which rooms are short a component.

A slot is a position in a room, and it has nothing to do with the roles under Admin that grant people access. Different word, different namespace, no overlap.

The standard’s blade carries a Slots panel beside its contract. Each slot has:

  • a name (its address within the standard, e.g. room-mic) and a label;
  • a quorum, how many components should fill it. Two ceiling mics is one slot with quorum 2, not two slots. The minimum is one, since a slot no component need fill is not a slot;
  • accepted types, the component types a filling component’s product may be classified under (self or a descendant); empty accepts any type. Optionally pinned products, narrowing further to specific products within an accepted type; empty accepts any product of an accepted type. This is the typed-slot guard: a slot wanting video-bar accepts the shipped Kestrel VRoom and any other product classified under it, but not a display;
  • an impact, what the room loses when this slot is not being filled properly.

Impact is the health knob, and it belongs to the slot. The same broken box matters differently depending on the job it was doing, so the judgement lives on the slot rather than on the device:

impactmeansreach for it when
outagethe room is not workingthe room cannot run without this slot
degraded (the default)the room works, worselosing it costs quality, not the meeting
nonenothingyou want the slot tracked, not depended on

A dead confidence monitor is not a dead main display, and this is where you say so. Set the main display to outage and the confidence monitor to none, and a failed confidence monitor stops paging anybody about a room that is running fine. What that impact does downstream is the health rollup: a slot short of its quorum contributes its impact, and the system takes the worst one.

Quorum is your redundancy setting, and it pairs with impact. A slot wanting one mic with two assigned survives losing either of them, because one working mic still meets the quorum. A slot wanting two with two assigned is impaired the moment either one fails. Redundancy is not a separate switch, it is the gap between what you staffed and what you need.

Declaring is idempotent, so saving a slot that already exists revises it in place, and the accepted types and pinned products each replace the previous set wholesale (drop one by leaving it out). Withdrawing a slot (with standard:delete, from edit mode like every contract control) also removes every assignment conforming systems made to it, so withdraw only when the slot itself is gone, not when one room’s component changed. Changing a quorum or an impact re-evaluates every conforming system immediately, so a retune shows up in the fleet’s health without waiting for anything to poll.

A standard created from a template arrives with the template’s slots, and they are the worked example: meeting-room’s Video Bar (accepts video-bar) and Main Display (accepts display), among others. Like the standard itself they are yours once created, so retuning a quorum to what your rooms actually run is never reverted by a restart or a release.

From the CLI: omniglass standard slot list meeting-room, omniglass standard slot update meeting-room <slot> --label <label> --quorum <n> --accepted-types <types> --pinned-products <ids> --impact <outage|degraded|none>, and omniglass standard slot delete meeting-room <slot>.

Declaring the slot is half of it; the other half happens on the system. Open a system from Explore and its detail carries a Slots panel showing every slot it needs filled: the ones inherited from its standard and any declared on the system itself, each marked with where it came from.

  1. Conform the system to the standard. A system’s Standard field is what makes it inherit; a one-off system that conforms to nothing sees only slots declared directly on it.
  2. Assign a component to the slot. Each slot lists the components filling it and lets you add another. The picker is scoped to what you can see, and assignment is idempotent. Staffing a slot makes the component a member of the system and writes onto it, so it takes component:update over the component as well as system:update over the system: a component you can see but not edit is refused with the scope named, and the same holds for unassigning one.
  3. Read the understaffed count. A slot wanting two components with one assigned reads as short by one, immediately, without any monitoring running: staffing is a fact about what you have entered. The room’s health asks the second question, of the components that are assigned, how many can currently do the job, and routes the answer up through the slot’s impact.
  4. Unassign when a component moves out. The slot goes back to understaffed until something else fills it. A component that is currently staffing a slot cannot be deleted; unassign it first, so the system never silently loses a slot.

A component that cannot fill the slot is refused, and told why. Assigning a display to a slot that accepts video-bar fails with a message naming both parties:

component "panel-1" is a display; slot "Table microphone" wants a video-bar

Pinning products narrows further: a right-type, wrong-product component is refused by name too:

component "panel-3" is product "other-display"; slot "Main Display" wants product boreal-edge-55

That is the whole point of the typed-slot guard. Your next move is in the message: either you picked the wrong component, or the slot’s accepted types (or pinned products) need widening.

Slots declared directly on a system work identically and are edited from the same panel; use them for what one room needs and the standard does not. A slot inherited from the standard is withdrawn on the standard, not on the system that inherits it. A slot declared on the system cannot reuse a name its standard already declares, since a slot is addressed by its name within the system and the name has to mean one slot there: declaring one, declaring the same name on the standard after a room took it, or moving a room onto a standard that declares a name the room declares itself is refused, naming both. A second slot takes a second name.

Moving a room to another standard keeps it staffed. Change a system’s Standard and each component filling an inherited slot carries across to the new standard’s slot of the same name, as long as it is still the kind of component that slot accepts and the slot has room. Anything else is released: it stays a member of the room with no slot, ready to be restaffed, unbound or deleted, and the room’s slots panel and health read the new standard at once. Clearing the Standard (making the room a one-off) releases every inherited slot’s staffing; slots declared on the room itself keep theirs. Moving back later reactivates nothing, so restaff what you want back.

From the CLI: omniglass system slot list <name>, omniglass system slot update <name> <slot>, omniglass system slot delete <name> <slot>, omniglass system slot assignment update <name> <slot> <component>, and omniglass system slot assignment delete <name> <slot> <component>.

Once the slots are declared and staffed, the whole loop (raise an alarm, watch the room go degraded, find the cause, clear it, read the history) is on Work with an entity.